EX59 Waterproof Compression F-type Connector
EX59 Waterproof Compression F-type Connector
  • Model
    SFJT-EX59CP
  • Brand
    Seehai
  • Price
    Call
  • Description

    High quality copper body with bright nickel plating

    Screw can bear torsion 30 of Pound*inch (about 3.5N*m), no screw stripped.

    About connecting with the cable, this kind of connector is more convenient to connect the cable than which connector is clamped to the cable.

Quantity :
Describe Product

The inside connector is with silicone rubber waterproof ring, to resist moisture and dust.

Applicable to the cable quad-shield of ES59, F59 HEC-2

Specifications

Specification:

No.

Item

Connector for RG6 cable

1

Connector Type

F-type (British)

2

Operating Frequency Range

5MHz1000MHz

3

Impedance

75Ω

4

Insertion Loss

5MHz300MHz

0.05dB

5

300MHz1000MHz

0.1dB

6

Return Loss

5MHz300MHz

30dB

7

300MHz1000MHz

30dB

8

Screening Attenuation

100dB

9

Contact Resistance

Inner Conductor

10mΩ

Outer conductor

5mΩ

10

Insulation ResistanceDC 500V

1000MΩ

11

Withstanding Voltage

AC 1.5KV, 1min, no breakdown

12

Water and fog resistantSCTE standard: ANSI/SCTE 60 2004 red dye120 hourshigh-low temperature cycletest condition please check Tips 1

No leakage

13

Water immersion test (24h)

Insulation resistance200MΩ, The resistance voltage meets the requirements of item 11

14

Resistance to damp heat test

Withstand voltage

800V

(40℃±2,93%±3%,24h×21)

Insulation resistance

250MΩ

(40℃±2,93%±3%,24h×21)

15

High temperature insulation resistance

500MΩ

(85℃±5,16h)

16

Low temperature insulation resistance

1000MΩ

(40℃±5,2h)

17

Working torque strength of connector

3.39 Newton-meters

18

The length of connector

after finished the compression

25mm

19

Connect strength of connector and cable (Double shield cable)

20kgs

20

Universality of connector

The same model connector can be used in F59 HEC-2 cable with double, triple and quad-shield.

21

Operating temperature

-40 - +60

Tips 1 SCTE standard: ANSI/SCTE 60 2004 Resistance to damp heat test method. Environmental temperature: upper limit 60±1, lower limit 1.7±1. Put the connector on this environment to test 120 hours, and looping 10 times on the temperature limits. Each cycle must be maintained at a maximum temperature of 300 + / -20 minutes.

Comment - Rating product